Report expires: 17/03/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Mar 17, 2026 | Mar 17, 2026 | 105-cox-hire-manitou-mt625-s-n-954581 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| COX hire Halesowen Road Dudley DY2 | Sunfield school woodman lane DY99PB |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| 105 Manitou MT625 telehandler s/n 954581 | Max 2500kg | Mar 17, 2026 | 2015 | 04-07-2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|