Report expires: 16/04/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Apr 16, 2025 | Apr 16, 2025 | 1513-eagle-plant-wolverhampton-jcb-telehandler-540-170-s-n-jcb5afngem3011063 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Eagle plant cross street Wolverhampton WV1 2HS | S E P properties prince thorpe way CV3 2HG |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| 1513 JCB telehandler 540-170 s/n JCB5AFNGEM3011063 | Max 4000kg | Apr 16, 2025 | 2021 | 03-05-2023 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|