Report expires:   06/07/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Jul 06, 2024 Jul 06, 2024 245-global-ardour-recycling-linde-h25d-02-s-n-351g1101125

Client details

   Name and address of employer           Address of the premesis      
Global ardour Preston PR2 5BX Global ardour Preston PR2 5BX

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
245 Linde H25D-02 s/n 351G1101125 Max 2500kg Jul 06, 2024 1996 04-07-2023
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Wear on bottom carriage rollers



Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP