Report expires: 29/09/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Sept 29, 2025 | Sept 29, 2025 | 4740-eagle-plant-bury-takeuchi-tb290-2-s-n-190502421 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Eagle plant Bury quest park Haywood Bury BL9 7JJ | CHCS aintree HSP Liverpool L9 7AL |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| 4740 Takeuchi TB290-2 s/n 190502421 hitch s/n 10122 | Max 1650kg | Sept 29, 2025 | 2020 | 17-10-2024 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|