Report expires:
26/05/2024
|
Report of thorough examination of lifting equipment
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
| Last Updated |
Date of report |
Report number |
| May 26, 2023 |
May 26, 2023 |
686-recycling-lives-bury-contact-plant-rental-still-forklift-rc42-50-2 |
Client details
| Address of the premesis |
| Recycling lives Bury BL9 5AL |
Equipment / Examination
| Description of the equipment |
Safe working load |
Date of exam |
Date of manufacture |
| 686 Still forklift RC42-50 s/n B16012X00181 |
Max 5000kg |
May 26, 2023 |
2020 N/A |
Defects
No defects |
| Is this the first examination after installation? |
Has the equipment been installed correctly? |
| no |
yes |
| Was the examination carried out? |
In accordance of the examination scheme? |
In exceptional circumstances? |
| In an interval of 12 months |
yes |
no |
| Particulars of any test carried out as part of the examination? |
Full test carried out |
| Is the above a defect which is immediate danger to persons |
no |
| Is the above a defect which is not yet but could become an immediate danger to persons |
no |
| Is this equipment safe to operate? |
Yes |
| Name of person authenticating this report: |
Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP |