Report expires: 22/01/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jan 22, 2026 | Jan 22, 2026 | 745-doosan-d50c-9-global-ardour-recycling-preston-s-n-fdb44-5110-00037 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Global ardour recycling Preston PR2 5BX | Global ardour recycling George Henry road DY4 7BZ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| 745 Doosan D50C-9 forklift s/n FDB44-5110-00037 | Max 2789 kg with attachment | Jan 22, 2026 | 2021 | 24-03-2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full weight test carried out at 152mm 350mm and 1016mm -2mm drop after 10 minutes each height. |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|