Report expires:   01/06/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Dec 01, 2024 Dec 01, 2024 ampthill-tidy-tip-fuchs-mhl250-s-n-250310-4083

Client details

   Name and address of employer           Address of the premesis      
Ampthill Tidy Tip Abbey lane Ampthill Bedford MK45 2SA Ampthill Tidy Tip Abbey lane Ampthill Bedford MO45 2SA

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
Fuchs MHL 250 s/n 250310/4083 with Arden S0802 rotating grab As per manufacturer’s guidelines Dec 01, 2024 2016 Unknown
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Slight weep from dipper arm pipes / valve

Pipe insecure l/h and right hand of boom


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP