Report expires: 25/10/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Apr 25, 2026 | Apr 25, 2026 | baileys-skip-hire-moffett-forklift-m8-s-n-0240188-2 |
| Address of the premesis | |||
|---|---|---|---|
| Baileys skip hire heritage way Corby NN17 5XW |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Moffett forklift M8 s/n 0240188 | Max 3000kg @ 600mm load centre | Apr 25, 2026 | 2015 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 6 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
| NONE |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|