Report expires: 20/04/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Apr 20, 2026 | Apr 20, 2026 | bennie-equipment-mitsubishi-fort-lift-fg35n-s-n-cf13g-51509 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Bennie eguipment Kettering NN15 5TB | Dumpster house Tyne and were NE31 1SP |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Mitsubishi FG35N forklift s/n CF13G-51509 | As per manufacturer’s guidelines | Apr 20, 2026 | Unknown | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|