Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Crane hill engineering Ltd Harvey reeves road NN5 5JR | Crane hill engineering Ltd Harvey reeves road NN5 5 JR |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Mechanical power press PP2 R4A C frame fixed | Max 50tons none lifting | Nov 13, 2024 | Unknown | Unknown |
Defects See below |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
Other defects: Toolsetters disconnect link roller arm taper pin worn - replace pin and secure arm Operating foot pedal to be shrouded to prevent accidental operation Stroke scotch arm taper pin worn - replace pin and secure arm Advise bolt press fully to floor Front guard interlock cup loose and cracked - repair/replace and secure Front guard bars bent/misaligned exposing gaps - straighten bars to close all gaps Observations: Play in Pitman Ball; 2.5mm, Play in Pitman Screw: 0mm, Play in Stroke Bearing: 0mm |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out to PUWER requirements |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|