Report expires: 13/11/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Nov 13, 2024 | Nov 13, 2024 | crane-hill-engineering-pp3-power-press-s-n-1-6068-1945 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Crane hill engineering Ltd Harvey reeves road NN5 5JR | Crane hill engineering Ltd Harvey reeves road NN5 5 JR |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Mechanical power press PP3 C-frame inclineable s/n 1-6068-1945 | Max 12 tons none lifting | Nov 13, 2024 | 1945 | Unknown |
Defects See below |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
Other defects: Gaps at top for front guard should be enclosed Fit suitable anti-fall back device Advise bolt press to floor Observations: Play in Pitman Ball: 0.7mm, Play in Pitman Screw: 0.1mm, Play in Stroke Bearing: 0.1mm, Flywheel and crankshaft scored - serviceable as per last clutch dismantle 23/11/18, Clutch key worn - serviceable as per last clutch dismantle 23/11/18 |
Particulars of any test carried out as part of the examination? |
---|
Front Guard: Automatic Side Guards: Fixed Rear Guards: Fixed Full test carried out to PUWER requirements |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|