Report expires: 30/10/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Oct 30, 2025 | Oct 30, 2025 | croft-contractors-hyundai-excavator-hx140-s-n-000360 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Croft contractors 23 Blackwood court Lancashire OL13 0BD | Barnfield site Wilson Road hyuton L36 6AD |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Hyundai HX140 s/n 000360 | As per manufacturer specifications/ lift chart | Sep 30, 2024 | 2023 | 30-09-2024 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|