Report expires: 17/04/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Sep 17, 2021 | Sep 17, 2021 | cte-zed26-j-truck-mount-5532 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
GAP Roofing Services Ltd | 125 - 133 Pollard Street, Manachester, M47JB |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
CTE ZED26 J Truck Mount 5532 | 230Kg | Apr 17, 2025 | 2012 | 0000-00-00 00:00:00 |
N/A |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | yes |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
None found upon inspection |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|