Report expires: 27/07/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Dec 27, 2024 | Dec 27, 2024 | dcv-2681-dcv-engineering-genie-lift-gs-1932-s-n-b200025306 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
DCV engineering Ltd Rixon road Wellingborough NN8 4BB | DCV engineering Ltd Rixon road Wellingborough NN8 4BB |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
DCV 2681 genie lift GS 1932 s/n B200025307 | Max 227kg | Dec 27, 2024 | 2019 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|