Report expires:
05/07/2026
|
Report of thorough examination of lifting equipment
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
| Last Updated |
Date of report |
Report number |
| Jul 05, 2025 |
Jul 05, 2025 |
dcv-2877-manitou-forklift-me-315-s-n-man00000l00864202 |
Client details
| Name and address of employer | Address of the premesis |
| DCV engineering Ltd Rixon road Wellingborough NN84BB | Wykes Wymington NN10 9LU |
Equipment / Examination
| Description of the equipment |
Safe working load |
Date of exam |
Date of manufacture | Date of last examination |
| DCV 2877 manitou ME 315 electric forklift s/n MAN00000L00864202 |
Max 1500kg |
Jul 05, 2025 |
2021 | 12/07/2024
|
Defects
None |
| Is this the first examination after installation? |
Has the equipment been installed correctly? |
| no |
yes |
| Was the examination carried out? |
In accordance of the examination scheme? |
In exceptional circumstances? |
| In an interval of 12 months |
yes |
no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
No defects |
| Particulars of any test carried out as part of the examination? |
Full test carried out |
| Is the above a defect which is immediate danger to persons |
no |
| Is the above a defect which is not yet but could become an immediate danger to persons |
no |
| Is this equipment safe to operate? |
Yes |
| Name of person authenticating this report: |
Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP |