Report expires: 01/08/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Aug 01, 2026 | Aug 01, 2026 | dcv-3013-extension-forks-dcv-engineering-s-n-178772 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| DCV engineering Ltd Rixon Road Wellingborough NN8 4BB | DCV Engineering Ltd Rixon Road Wellingborough NN8 4BB |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| DCV 3013 Extension forks for merlo s/n 178772 | As per manufacturer specifications | Aug 01, 2026 | 2023 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|