Report expires: 18/09/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Sep 18, 2025 | Sep 18, 2025 | dcv-3035-merlo-zm3-wide-forklift-s-n-1314440005 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| DCV engineering Ltd Rixon Road Wellingborough NN8 4BB | DCV engineering Ltd Rixon Road Wellingborough NN8 4BB |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| DCV 3035 Merlo ZM3 wide forklift s/n 1314440005 | Max 7500kg | Sep 18, 2025 | 2023 | 07/10/2024 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|