Report expires: 09/04/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Apr 09, 2026 | Apr 09, 2026 | dcv-3041-merlo-telehandler-tf38-10-s-n-d2004960 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| DCV engineering Ltd Wellingborough NN8 4BB | DCV engineering Ltd Wellingborough NN8 4BB |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| DCV 3041 Merlo TF38.10 Telehandler s/n ZF1P50TG6D2004960 Reg KX24 AXF | Max 3800kg | Apr 09, 2026 | 2024 | 09/05/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|