Report expires:   04/08/2026  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Feb 04, 2026 Feb 04, 2026 dcv-3254-snorkel-s3219plus-s-n-260200397

Client details

   Name and address of employer           Address of the premesis      
DCV Engineering Ltd, Rixon Road, Wellingborough, NN8 4BB DCV Engineering Ltd, Rixon Road, Wellingborough, NN8 4BB

Equipment / Examination

N/A
Description of the equipment Safe working load Date of exam Date of last examination
DCV 3254 Snorkel S3219Plus MEWP s/n S3219P-01-260200397 272kg Feb 04, 2026 Declaration of conformity

N/A

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no


Particulars of any test carried out as part of the examination?
NONE

Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP