Report expires: 03/06/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jun 03, 2026 | Jun 03, 2026 | dcv-3277-lift-n-lock-500-4-30-hydraulic-boom-gantry |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| DCV Engineering Ltd, Rixon Road, Wellingborough, NN8 4BB | Rixon Road, Wellingborough, NN8 4BB |
| Description of the equipment | Safe working load | Date of exam | Date of last examination |
|---|---|---|---|
| DCV 3277 J & R Engineering Lift n Lock 500-4-30 Hydraulic Boom Gantry | Max 226 Tonnes with 4 Lift Housings/ Max 113 Tonnes with 2 Lift Housings | Jun 03, 2026 | N/AUnknown |
| Defects None |
|||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|