Report expires: 29/01/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jan 29, 2026 | Jan 29, 2026 | e20-1004-premier-plant-hire-hitachi-20t-excavator |
| Address of the premesis | |||
|---|---|---|---|
| Premier plant hire Narborough LE192GA. Winvic, DIRFT, NN6 7GZ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| E20-1004 Hitachi ZX210 LC-6 Excavator s/n HCMDC451A00510490 | As per manufacturer's guidelines | Jan 29, 2026 | 2021 | 31/01/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|