Report expires:   09/05/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Nov 09, 2024 Nov 09, 2024 ea64-pku-baileys-skip-hire-hyva-lift-chain-inspection-s-n-27406593

Client details

      Address of the premesis      
Baileys skip hire heritage way Corby NN17 5XW

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
EA64 PKU chain inspection Baileys skip hire Hyva body s/n 27406593 Max 12000kg Nov 09, 2024 2014 Unknown
Defects
None

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

No defects


Particulars of any test carried out as part of the examination?
NONE

Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP