Report expires: 29/05/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| May 29, 2026 | May 29, 2026 | f10-1002-merlo-telehandler-p30-10-fj24-eyz |
| Address of the premesis | |||
|---|---|---|---|
| Premier Plant Hire, Narborough, LE19 2GA. Kingston Park, PE2 9EN |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| F10-1002 Merlo P30.10 Telehandler s/n ZF1P50TE8D2000375 Reg FJ24EYZ | Max 3000kg | May 29, 2026 | 2022 | 05/06/2025 |
| Defects NONE |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|