Report expires: 19/02/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Feb 19, 2024 | Feb 19, 2024 | f20-1002-preimer-plant-jcb-telehandler-540-200-s-n-2791427 |
Address of the premesis | |||
---|---|---|---|
Thomas street Bristol BS1 6JS |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
F20-1002 JCB Telehandler 540-200 s/n 2791427 | Max 4000kg | Feb 19, 2024 | 2019 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
Boom pipe starting to wear |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|