Report expires:   18/05/2027  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
May 18, 2026 May 18, 2026 f23-ndlt-uk-timber-tider-fd40-s-n-224022579

Client details

   Name and address of employer           Address of the premesis      
NDLT Burkitt Road Corby NN17 4DT UK timber Weldon Road Corby

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
F23 Tider FB35 Counterbalance FLT s/n 224022579 Hours 2714 3000kg @ 500mm load centre May 18, 2026 2024 27/05/2025
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Fork heels 47mm/50mm, Chain wear primary 0.5% secondary 0.25%

Top lamps damaged


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP