Report expires:   18/05/2027  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
May 18, 2026 May 18, 2026 f24-tider-fd25-ndlt-forklift-s-n-240587982

Client details

   Name and address of employer           Address of the premesis      
NDLT Burkitt Road Corby NN17 4DT Uk Timber, Wansell Road, Corby, NN17 5LX

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
F24 Tider FB25 Counterbalance FLT s/n 240587982 Hours 1113 Max 2500kg May 18, 2026 2024 27/05/2025
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Fork heels 38mm/40mm, Chain wear primary 0.25% secondary 0.25%

Flashing beacon lights up but doesn't flash


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP