Report expires: 04/07/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jul 04, 2025 | Jul 04, 2025 | g-osullivan-plant-hire-thwaites-9-ton-forward-tip-dumper-s-n-d9142 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| G O’Sullivan plant hire Daventry NN11 3HT | G O’Sullivan plant hire Daventry NN11 3HT |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Theatres 0 ton forward tip dumper s/n SLCM20981701D9142 | Max load tipped /carried 9000kh | Jul 04, 2025 | 2017 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|