Report expires: 06/12/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Dec 06, 2024 | Dec 06, 2024 | gfc-jcb-telehandler-531-70-s-n-3060854 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
GFC Headlandhouse kings court Kettering NM15 6WJ | Railway triangle Walton Road Portsmouth PO6 1TS |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
JCB Telehandler 531/70 s/n JCB5AAMGPM3060854 | Max 4100kg | Dec 06, 2024 | 2021 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|