Report expires:   27/02/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Aug 27, 2024 Aug 27, 2024 global-ardour-recycling-ltd-genie-z45-s-n-z452512b-2274

Client details

   Name and address of employer           Address of the premesis      
Global ardour recycling Ltd Preston PR2 5BX Global ardour recycling Hitchin SG4 0SE

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
Genie Z45 s/n Z452512B-2274 Max 227 kg Aug 27, 2024 2012 Unknown
Defects
None

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Slight hose leak on boom near basket


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP