Report expires: 27/02/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Aug 27, 2024 | Aug 27, 2024 | global-ardour-recycling-ltd-genie-z45-s-n-z452512b-2274 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Global ardour recycling Ltd Preston PR2 5BX | Global ardour recycling Hitchin SG4 0SE |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Genie Z45 s/n Z452512B-2274 | Max 227 kg | Aug 27, 2024 | 2012 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
Slight hose leak on boom near basket |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|