Report expires: 03/11/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Nov 03, 2025 | Nov 03, 2025 | jcb01-wilby-tree-services-jcb-telehandler-533-s-n-jcb5ahjgl61191173 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Wilby tree surgeons Ltd Tower field farm Northampton NN6 0QT | Wilby tree surgeons Ltd Tower field farm Northampton NN6 0QT |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| JCB01 Telehandler 533 s/n JCB5AHJGL61191173 | Max 3300kg | Nov 03, 2025 | 2006 | Unknown |
| Defects See below |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
Slight weep from leg ram L/H Carriage pin loose (tilt) Hand brake poor |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|