Report expires: 30/10/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Oct 30, 2025 | Oct 30, 2025 | kx030-4-croft-contractors-ltd-kubota-3t-excavator-s-n-1140 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Croft contractors ltd 23 blackwood court stacksteads lancs OL130BD | Barnfield site wilson rd Huyton L366AD |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Kubota 3t excavator kx030-4 s/n 1140 | 1480kg | Oct 30, 2025 | 2019 | 30/09/2024 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
None |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|