Report expires:   08/12/2023  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Jun 08, 2023 Jun 08, 2023 laf-22-recycling-lives-glasgow-fuchs-mhl360-s-n-360310-4025-2

Client details

      Address of the premesis      
Recycling lives Glasgow G51 4SD

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture
LAF22 Fuchs MHL360 s/n 360310/4025 Max 1600kg m3 material handled Jun 08, 2023 2012 N/A
Defects
Slight Hydrolic leak from rear of cab and engine . Seat belt catch damaged. X2 grab ram guards missing

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Full test carried out


Particulars of any test carried out as part of the examination?
NONE

Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP