Report expires: 04/05/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Nov 04, 2024 | Nov 04, 2024 | lc-10-spitfire-engineering-services-ltd-ibc-cage |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Spitfire engineering services Ltd Brixworth NN6 9DS | Spitfire engineering services Ltd Brixworth NN6 9DS |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
LC-10 IBC cage | Max 1200kg | Nov 04, 2024 | 2024 | First examination |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
yes | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|