Report expires: 16/04/2026 |
Last Updated | Date of report | Report number |
---|---|---|
Apr 16, 2025 | Apr 16, 2025 | lk19-jkj-daf-palfinger-crane-m125l82-s-n-2336799 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
FD plant 12 Broadlands Raunds NN9 6QL | FD plant 12 Broadlands Raunds NN9 6QL |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
LK18 JKJ DAF Palfinger crane M125L82 | Max 2220kg @ 5 meters 1350kg @ 8 meters | Apr 16, 2025 | 2017 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|