Report expires:
06/11/2024
|
Report of thorough examination of lifting equipment
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998
Last Updated |
Date of report |
Report number |
Nov 06, 2023 |
Nov 06, 2023 |
ls418-paul-chapman-and-sons-ltd-volvo-wheeled-loader-l260h-s-n-a00001009 |
Client details
Name and address of employer | Address of the premesis |
Paul chapman and sons Ltd High peak Junction Derby road Cromford DE4 5HN | Hindlow quarry SK17 9QD |
Equipment / Examination
Description of the equipment |
Safe working load |
Date of exam |
Date of manufacture | Date of last examination |
LS418 Volvo wheeled loader L260H s/n VCEL260HA00001009 |
Max 6.4m3 bucket |
Nov 06, 2023 |
2017 | Unknown
|
Defects
None |
Is this the first examination after installation? |
Has the equipment been installed correctly? |
no |
yes |
Was the examination carried out? |
In accordance of the examination scheme? |
In exceptional circumstances? |
In an interval of 12 months |
yes |
no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
No defects |
Particulars of any test carried out as part of the examination? |
Full test carried out |
Is the above a defect which is immediate danger to persons |
no |
Is the above a defect which is not yet but could become an immediate danger to persons |
no |
Is this equipment safe to operate? |
Yes |
Name of person authenticating this report: |
Andrew Sands
The Loler Man - NN15 6TP |