Report expires: 28/03/2026 |
Last Updated | Date of report | Report number |
---|---|---|
Mar 28, 2025 | Mar 28, 2025 | lx23-xob-nu-stone-hmf-crane-1420k-s-n-145-0264 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Nu stone Kettering NN14 3JW | Nu stone Kettering NN14 3JW |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
LX23 XOB HMF crane 1420K RCS s/n 145 0264 with kinshofer KM331.1300 s/n GG09314 | Max 3010kg @ 4.3 meters / 1530kg 8.3 meters | Mar 28, 2025 | 2021 | Unknown |
Defects No defects |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|