Report expires:   19/02/2026  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Aug 19, 2025 Aug 19, 2025 mewp01-wilby-tree-teupen-leo-15ct-s-n-140314

Client details

   Name and address of employer           Address of the premesis      
Wilby tree surgeons Northampton NN6 0QT Wilby tree surgeons Northampton NN6 0QT

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
MEWP 01 LEO 15 CT s/n 140314 Max 200kg Aug 19, 2025 2006 Unknown
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 6 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Hose to vale block showing signs of wear


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP