Report expires: 09/01/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Jan 09, 2026 | Jan 09, 2026 | murry-steel-works-ltd-mitsubishi-fg25k-forklift-s-n-66088 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Murry steelworks Ltd Romford RM1 1SX | Murry steelworks Ltd Romford RM1 1SX |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Mitsubishi FG25K forklift s/n EF17B-66088 | Max 2500kg | Jan 09, 2026 | 2003 | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
Tilt ram damp ( not leaking ) |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|