Report expires: 10/03/2026 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Sep 10, 2025 | Sep 10, 2025 | mvm000151-fork-extension-attachment-ewl-1400mm-swl625kg |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| MVM group Milton Keynes MK9 1LR | MVM group Milton Keynes MK9 1LR |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| MVM 000151 fork extension attachment | EWL1400mm max 625kg | Sep 10, 2025 | Unknown | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 6 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|