Report expires: 09/08/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Feb 09, 2025 | Feb 09, 2025 | mx16-fgf-daf-lf-tail-lift-model-s1500g-s-n-unknown |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Think3e Consortuim links road Wellingborough NN8 4EY | Think3e Consortuim links road Wellingborough NN8 4EY |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
MX16 FGF DAF Lf Del tail lift model S1500G s/n unknown | Max 1500kg | Feb 09, 2025 | 2016 | 06-09-2024 |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 6 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|