Report expires: 05/03/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Mar 05, 2026 | Mar 05, 2026 | ndlt-forklift-30d-7e-s-n-hhihh05ha0001112 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| NDLT 30 Burkit Road Corby NN17 4DT | UK Timber, Wansell Road, Corby, NN17 5LX |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Hyundai 30D-7E Counterbalance FLT s/n HHIHHN04HA0001112 hours 13760 | Max 2950 kg @ 500mm centre | Mar 05, 2026 | 2010 | 11/03/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
Fork heels 44mm/45mm, Chain wear 1.25% Rear tyres worn requiring replacement |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|