Report expires: 26/02/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Feb 26, 2024 | Feb 26, 2024 | ndlt-forklift-30d-7e-s-n-hhihh05ha0001112 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
NDLT 30 Burkit Road Corby NN17 4DT | Wansell Road Corby NN17 5LX |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Hyundai 30D-7E forklift s/n HHIHHN04HA000112 | Max 2950 kg @ 500mm centre | Feb 26, 2024 | 2010 | Unknown |
Defects See below |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
Rear tyres low / no tread Steering cowling damage / insecure Steering wheel worn/ damaged Steering knob damaged |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|