Report expires:   18/05/2027  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
May 18, 2026 May 18, 2026 ndlt-uk-timber-cat-dp50-s-n-50047

Client details

   Name and address of employer           Address of the premesis      
NDLT Burket Road corby NN17 4DT Brigstock Sawmill, NN14 3HP

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
F18 CAT Forklift DP50K s/n ET28B-50047 Hours 10566 5000kg @ 600mm load centre May 18, 2026 2001 02/06/2025
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Fork Heels 55mm/60mm, Chain wear 0.5%,

Fork heels approaching 10% wear limit and tips are worn,

Side shift hydraulic hose is tight but leaks,

Seat base and back require replacement,

Flashing beacon and reverse alarm missing,

New ignition barrel required as key is snapped off,

Dash instruments inoperative,


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP