Report expires:   13/06/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Jun 13, 2024 Jun 13, 2024 ndlt-uk-timber-hyundai-25d-7-forklift-s-n-ha0210172

Client details

   Name and address of employer           Address of the premesis      
NDLT forklifts 30 Burkitt Road Corby NN17 4DT Uk timber Corby NN17 4DT

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
Hyundai 25D-7 forklift s/n HA0210172 with CAM rotator PRC 22D Hours 7066 Max 1600kg Jun 13, 2024 2009 Unknown
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Seat damaged

Chains nearly at max wear



Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP