Report expires: 27/02/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Feb 27, 2026 | Feb 27, 2026 | ndlt-yale-gdp35vx-counterbalance-flt-s-n-b875b22327j |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| NDLT, 30 Burkitt Road, Corby, NN17 4DT | UK Timber, Corby, NN17 5UE |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Yale GDP35VX Counterbalance FLT s/n B875B22327J hours 10521 | 2900kg @ 500mm load centre | Feb 27, 2026 | 2011 | 10/03/2025 |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
Fork heels 42mm/45mm, Chain wear 0.5% Handbrake requires adjustment, windscreen cracked requiring replacement |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|