Report expires: 19/03/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Mar 19, 2026 | Mar 19, 2026 | pdi-unicarriers-jag2n1l20q-counterbalance-flt-c-w-clamp-attachment-s-n-jag2n1e701123 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| PDI International, Pywell Road, Corby, NN17 5XJ | Site A, Pywell Road, Corby, NN17 5XJ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Unicarriers JAG2N1L20Q Counterbalance FLT s/n JAG2N1E701123 c/w Rotating Roll Clamp Attachment s/n BWDA7079 | 1135kg @ 650mm load centre | Mar 19, 2026 | 2020 | Unknown |
| Defects Oil leak on clamp attachment is awaiting repair |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|