Report expires: 23/09/2025 |
Last Updated | Date of report | Report number |
---|---|---|
Sep 23, 2024 | Sep 23, 2024 | peter-ashley-limited-bobcat-s590-s-n-azne11066 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Peter Ashley limited 38 Moss lane Styal Wilmslow Cheshire SK9 4LG | Unit P1-17 Haywood distribution park Pilsworth Road Haywood OL10 2TT |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Bobcat S590 s/n AZNE11066 | Max 950kg as per manufacturer specifications | Sep 23, 2024 | 2014 | Unknown |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|