Report expires: 13/02/2027 |
| Last Updated | Date of report | Report number |
|---|---|---|
| Feb 13, 2026 | Feb 13, 2026 | phoenix-brickwork-caterpillar-gp25-flt-s-n-6an00080 |
| Name and address of employer | Address of the premesis | ||||||
|---|---|---|---|---|---|---|---|
| Phoenix Brickwork Ltd, 37 Crow Lane, NN3 9BZ | 37 Crow Lane, Northampton, NN3 9BZ |
| Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
|---|---|---|---|---|
| Caterpillar GP25 Counterbalance FLT s/n 6AN00080 | 2000kg @ 500mm load centre | Feb 13, 2026 | Not marked | Unknown |
| Defects None |
||||
| Is this the first examination after installation? | Has the equipment been installed correctly? |
|---|---|
| no | yes |
| Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
|---|---|---|
| In an interval of 12 months | yes | no |
| Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
|---|
No defects |
| Particulars of any test carried out as part of the examination? |
|---|
Full test carried out |
| Is the above a defect which is immediate danger to persons | no |
|---|---|
| Is the above a defect which is not yet but could become an immediate danger to persons | no |
| Is this equipment safe to operate? | Yes |
|---|
| Name of person authenticating this report: | Andrew Sands BAGMA Approved Thorough Examiner BAGMA ID: 210011893 The Loler Man - NN15 6TP |
|---|