Report expires:   21/06/2025  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Jun 21, 2024 Jun 21, 2024 pioneer-plant-jcb-560-80-telehandler-s-n-3094594

Client details

   Name and address of employer           Address of the premesis      
Pioneer plant Corby NN17 4JW Encycilis Ltd green lane Bedford MK43 9LY

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
JCB Telehandler 560-80 s/n JCB4BR0WJM3094595 Max 6000kg Jun 21, 2024 2022 Unknown
Defects
See below

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

Front carriage and pins slight play

Front ram cover insecure

Poss boom hoses twisted ( needs further investigation)


Particulars of any test carried out as part of the examination?

Full test carried out


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
The Loler Man - NN15 6TP