Report expires:   26/11/2026  

Report of thorough examination of lifting equipment

This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998


    Last Updated       Date of report         Report number    
Nov 26, 2025 Nov 26, 2025 pta-longcliffe-ltd-abac-genesis-11-270l-air-compressor-c-w-air-com-horizontal-welded-air-receiver

Client details

   Name and address of employer           Address of the premesis      
PTA (Longcliffe) Ltd Haven Hoe Garage, Longcliffe, DE4 4HN

Equipment / Examination

Description of the equipment Safe working load Date of exam Date of manufacture Date of last examination
ABAC Genesis 11 270L air compressor s/n ITJ883092 c/w Air Com horizontal welded air receiver s/n 001019 Working Pressure 13 Bar, Max Pressure 13 Bar Nov 26, 2025 2024 Declaration of conformity
Defects
None

Is this the first examination after installation? Has the equipment been installed correctly?
no yes

Was the examination carried out? In accordance of the examination scheme? In exceptional circumstances?
In an interval of 12 months yes no

Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect:

No defects


Particulars of any test carried out as part of the examination?

Thorough visual examination and functional test carried out.

Air receiver thickness measured @ 4.2mm using ultrasonic gauge. Unit considered to be in good and safe working order at time of inspection, suitable for further service.


Is the above a defect which is immediate danger to persons no
Is the above a defect which is not yet but could become an immediate danger to persons no
Is this equipment safe to operate? Yes

Name of person authenticating this report: Andrew Sands
BAGMA Approved Thorough Examiner
BAGMA ID: 210011893
The Loler Man - NN15 6TP