Report expires: 24/11/2024 |
Last Updated | Date of report | Report number |
---|---|---|
Nov 24, 2023 | Nov 24, 2023 | q-4796-eagle-plant-bury-extension-forks-s-n-164135 |
Name and address of employer | Address of the premesis | ||||||
---|---|---|---|---|---|---|---|
Eagle plant quest park bury BL9 7JJ | Eagle plant quest park Bury BL9 7JJ |
Description of the equipment | Safe working load | Date of exam | Date of manufacture | Date of last examination |
---|---|---|---|---|
Q 4796 Extension forks s/n 164135 | Max as per manufacturer | Nov 24, 2023 | 2022 | Certificate of Confirmation |
Defects None |
Is this the first examination after installation? | Has the equipment been installed correctly? |
---|---|
no | yes |
Was the examination carried out? | In accordance of the examination scheme? | In exceptional circumstances? |
---|---|---|
In an interval of 12 months | yes | no |
Identification of any part found to have a defect which is or could become a danger to persons and a description of this defect: |
---|
No defects |
Particulars of any test carried out as part of the examination? |
---|
Full test carried out |
Is the above a defect which is immediate danger to persons | no |
---|---|
Is the above a defect which is not yet but could become an immediate danger to persons | no |
Is this equipment safe to operate? | Yes |
---|
Name of person authenticating this report: | Andrew Sands The Loler Man - NN15 6TP |
---|